We thinks what prospects think, the urgency of urgency to act from the interests of a client position of theory, allowing for greater high-quality, reduced processing costs, rates are much more reasonable, won the new and previous consumers the support and affirmation for Elevator Safety Gear, Gearless Elevator Motor, Wire Lifting, Customers first! Whatever you require, we should do our utmost to help you. We warmly welcome customers from all over the world to cooperate with us for mutual development.
2021 High quality Elevator Door Motor - 2-Leafs Center Opening Landing Door Device THY-LD-B – Tianhongyi Detail:

1. The unlocking method is to unlock the door panel and pass the 45Kg pendulum impact test.

2. The door is forced to close by a heavy hammer, and the heavy hammer and the guide tube are placed on the inner side of the landing door.

3. The door lock has passed the test of the National Elevator Inspection Center and obtained CE and CU-TR certification.

4. Applicable voltage of door lock: ≤ AC230V, ≤ DC110V.

2

1. Installation of sill and door cover

1.1. Determine the entry and exit position of the sill according to the size of the hoistway; adjust the center of the sill to be the same as the center of the entrance and exit, and mark the center of the sill; adjust the level of the sill to be less than 1/1000; Surface to prevent water from entering the hoistway.


1

1.2. Assemble the door cover column and the door cover door with connecting pieces, and install the hanging fixing parts; put the door on the sill, adjust the verticality of the door cover column to be less than 1/1000; the center of the door cover is consistent with the center of the entrance and exits Sill center mark measurement; the size of the lower forehead plane of the door cover and the upper plane of the sill is the net door height. After the adjustment is completed, lock the M8 flange nut. After adjusting the size, fix the column connector to the wall.

1.3. Fix the landing door toe guard on the sill.

2. Installation of landing door device


2

2.1. Align the upper sill frame of the landing door with the barb at the lower end of the suspension fixing part, and lock the upper sill frame and the suspension fixing part of the landing door through the M8*20 bolt group.

2.2. Fix the upper sill mounting frame on the hoistway wall with expansion bolts or through-wall bolts. The upper sill mounting frame and the landing door upper sill are connected by M8 square neck bolts.

2.3. Adjust the upper sill of the landing door left and right to make the center of the door open and the center of the entrance and exit consistent.

2.4. Adjust the verticality of the floor of the landing door device. Adjust the verticality of the floor of the landing door device to ±0.5mm by laying a vertical line or taking the car door sill as a reference.

2.5 After reviewing the main parameters of the installation of the sill frame on the following floor doors, tighten all the installation bolts:

Height of the upper sill frame of the landing door: the distance between the top surface of the upper sill frame guide rail of the landing door and the sill of the landing door is HH+106mm;

The center of the upper sill frame of the landing door: the deviation between the center of the upper sill frame of the landing door and the center of the entrance and exit is ±1mm;

The distance between the upper sill guide rail of the landing door and the sill of the car door: the distance between the upper sill guide rail of the landing door and the sill of the landing door is 42.5mm, and the distance from the sill of the car door is 72.5mm.

Height of the upper sill frame of the landing door: the distance between the top surface of the upper sill frame guide rail of the landing door and the sill of the landing door is HH+106mm;

The center of the upper sill frame of the landing door: the deviation between the center of the upper sill frame of the landing door and the center of the entrance and exit is ±1mm;

The distance between the upper sill guide rail of the landing door and the sill of the car door: the distance between the upper sill guide rail of the landing door and the sill of the landing door is 42.5mm, and the distance from the sill of the car door is 72.5mm.


3


1 (2)


1 (1)


Product detail pictures:

2021 High quality Elevator Door Motor - 2-Leafs Center Opening Landing Door Device THY-LD-B – Tianhongyi detail pictures


Related Product Guide:

We'll make each hard work to become excellent and excellent, and speed up our measures for standing from the rank of intercontinental top-grade and high-tech enterprises for 2021 High quality Elevator Door Motor - 2-Leafs Center Opening Landing Door Device THY-LD-B – Tianhongyi , The product will supply to all over the world, such as: luzern, Bangladesh, Mozambique, As an experienced manufacturer we also accept customized order and we could make it the same as your picture or sample specification. The main goal of our company is to live a satisfactory memory to all the customers, and establish a long term business relationship with buyers and users all over the world.
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Sabina from Kenya - 2017.12.19 11:10
    The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Stephanie from Pretoria - 2018.06.03 10:17

    Send your message to us:

    Send your message to us:

    Write your message here and send it to us